Solar battery calculator
Find a starting home battery and solar system
Enter your ZIP code, how you use electricity, how long you need power, and the appliances you want to keep running. Regular results show two options: a TIGER T4-72 all-in-one system, and an ELEPHANT system with 12 kW split-phase hybrid inverter(s) and ELEPHANT battery cabinets. Battery size comes from your monthly electricity use and how long you need power. Appliance choices size inverter power and motor surge. Off-grid plans size a 595W solar array so typical daily production can cover your daily use. Backup plans do the same when you choose “I want to add solar.” Peak sun hours use your state average when a U.S. ZIP code can be matched. If a commercial plan needs more than 100 kWh of battery storage, a PVBAT engineer should match the system. This is a starting estimate, not a guarantee.
1What do you need this system for?
Backup power covers an outage for the time you choose. Off-grid plans for daily energy without relying on the utility. In both cases, battery size follows your monthly usage and this duration.
2ZIP code
Optional, but encouraged. For off-grid plans, and for backup plans when you choose to add solar, we use it to look up a state average for peak sun hours when sizing 595W panels. If we cannot match your ZIP, we use 4.5 peak sun hours and say so in the result.
Enter a 5-digit U.S. ZIP code. Peak sun hours come from state annual averages based on NREL PVWatts / NSRDB data.
3Do you already have solar?
If you choose “I want to add solar,” this estimate lists how many 595W panels are needed so typical daily production can cover your daily use, for both backup and off-grid plans. Off-grid plans also size panels when you are not already fully covered by an existing array. If you already have solar, existing capacity is counted first, and only a shortfall is sized with additional panels.
4Monthly electricity usage
Choose how to enter usage. “From my bill” is the most accurate. A quick estimate uses published U.S. household averages and is a planning value, not a measurement.
Enter monthly kWh from your bill, or leave kWh blank and enter your monthly dollar amount plus the rate from your bill. If both kWh and dollars are entered, the kWh value is used.
Monthly usage (kWh)
The 18.16 ¢/kWh prefill is the U.S. EIA residential average for August 2026 (Electric Power Monthly Table 5.3, preliminary, released October 23, 2026). Enter the rate from your own bill if you have it. Conversion: kWh = dollars ÷ (rate in $/kWh).
This uses EIA Residential Energy Consumption Survey (RECS) 2020 Table CE2.1 average annual site electricity use by home size, optionally scaled by the RECS average for your household size relative to the U.S. average of 10,566 kWh/year (revised March 2024). It is a planning average, not a measurement of your home.
5Planned backup duration
How long you want stored energy to last during an outage. This, with your monthly usage, sets the battery size.
6Main electrical loads
Choose home or commercial, then select the U.S. appliances you want to power. These choices size inverter power and motor surge only, not battery size. Typical watts are planning values, not your nameplate.
Backup coverage (optional shortcut)
These shortcuts pre-check a starting list. You can still edit the appliances. Essentials covers typical outage basics (refrigerator, lights, and Wi-Fi). Whole home does not pre-check a 5-ton central air conditioner.
No appliances selected yet. Power and runtime will use monthly usage only.
Battery size comes from your monthly electricity use and how long you need power. Appliance choices size inverter power and motor surge, and are treated as if they may run at the same time. Regular results show two options: a TIGER T4-72 all-in-one system, and an ELEPHANT system with 12 kW split-phase hybrid inverter(s) and ELEPHANT battery cabinets. TIGER solar input is 90–230 V, max 8 kW; if a sized 595W array would need more than 8 kW, this estimate recommends adding an extra MPPT. Off-grid plans, and backup plans when you choose “I want to add solar,” size a 595W solar array so typical daily production can cover your daily use. If a commercial plan needs more than 100 kWh of battery storage, a PVBAT engineer should match the system. This is a starting estimate, not a guarantee. Confirm nameplates with a licensed electrician before you order. Rated kWh is not the same as usable kWh.
Frequently asked questions
How does this PVBAT solar battery calculator work?
You can optionally enter a U.S. ZIP code, then choose backup power or off-grid, how long you need power, and how to enter electricity use: from your bill (monthly kWh and/or a dollar amount) or a quick estimate using EIA RECS 2020 Table CE2.1 averages. If you enter a bill in dollars without kWh, the calculator can convert it using the rate you enter, or the U.S. EIA residential average of 18.16 ¢/kWh for August 2026 (Electric Power Monthly Table 5.3, preliminary). Appliance selections size inverter power and motor surge. Regular results show two options. This is a starting estimate, not a guarantee or a final specification.
Which systems does it show?
Regular results show two options. Option A is a TIGER T4-72 all-in-one system. TIGER storage is matched in rated 24 kWh, 48 kWh, and 72 kWh steps from your monthly kWh and the backup hours or off-grid days you choose. Extra TIGER batteries add energy only; power stays 13 kW continuous and 26 kW surge. Option B is an ELEPHANT system: 12 kW split-phase hybrid inverter(s) plus ELEPHANT 32.15 kWh cabinets, sized from the same energy need and from running and surge load. Selecting a large central air conditioner does not by itself remove the TIGER option or auto-upgrade the equipment. If the load exceeds TIGER’s 13 kW continuous or 26 kW surge ratings, the TIGER option is flagged for review, and the ELEPHANT option is sized with enough inverters.
How is battery size calculated?
For backup power, battery size is monthly kWh ÷ 30 × backup hours ÷ 24. For off-grid, it is monthly kWh ÷ 30 × off-grid days. Selected appliances size inverter power and surge, not battery kWh. Rated kWh is not the same as usable kWh.
When does a plan need engineer matching?
If the load category is Commercial and the planned battery storage is greater than 100 kWh, the calculator does not auto-select a standard TIGER or ELEPHANT kit. It shows an engineer-matching state, with the calculated storage and power figures as a reference, so a PVBAT engineer can match the system. Home plans are not forced into engineer matching solely because storage is above 100 kWh.
Does a backup plan include solar panels?
A backup plan includes a 595W panel count only if you choose “I want to add solar.” Off-grid plans size additional array capacity when it is needed to cover typical daily use. If a backup plan is set to “No” for solar, the calculator does not automatically size panels.
How are 595W panels sized?
Typical daily production per 595W panel is estimated as 0.595 × peak sun hours × 0.85. The panel count is the daily energy need (monthly kWh ÷ 30) divided by that figure, rounded up. Peak sun hours use a state annual average compiled from NREL PVWatts / NSRDB when a U.S. ZIP code can be matched; otherwise the calculator uses 4.5 peak sun hours. TIGER solar input is 90–230 V, max 8 kW (about 13 of these 595W panels on the TIGER input). If the sized array would need more than 8 kW of solar input, the TIGER option recommends adding an extra MPPT. String voltage is not automatically checked. Each 12 kW inverter on the ELEPHANT option can accept up to 13 kW of PV (6.5 kW × 2 MPPT).
Is this a final equipment specification?
No. This is a starting estimate. Confirm nameplates with a licensed electrician before you order. Results do not mean every selected load can run at the same time.
Battery Incentive Review
Federal and state incentive rules change by year, location, ownership model, and installation date. Ask your installer or tax advisor about current residential, commercial, and state programs before purchasing.